2018 irc roof sheathing requirements

R905.2Asphalt shingles. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum 3 / 8 -inch-diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than 3 / 4 inch (19.1 mm) into the roof sheathing. Galvanized fasteners shall be used for steel roofs. Paint systems in accordance with ASTM A755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A792, ASTM A875, ASTM A463, or ASTM A653. Wood shakes shall comply with the requirements of Table R905.8.5. For SI: 1 ounce per square foot = 0.305 kg/m, The installation of modified bitumen roofing shall comply with the provisions of this section and the manufacturer's, Modified bitumen roofing shall have a design. Mineral-surfaced roll roofing shall conform to ASTM D3909 or ASTM D6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions. The installation of wood shakes shall comply with the provisions of this section. Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. Same as Maximum Ultimate Design Wind Speed, Preservative-treated shakes and shingles of, Fire-retardant-treated shakes and shingles of, Preservative-treated tapersawn shakes of Southern pine treated in accordance with AWPA Standard U1 (Commodity Specification A, Special Requirement 4.6), Forest Products Laboratory of the Texas Forest Services, Preservative-treated tapersawn shakes of Southern Yellow Pine, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet. Where the existing roof covering is wood shake, slate, clay, cement or asbestos-cement tile. Rooftop-mounted photovoltaic systems shall be installed in accordance with the manufacturer's instructions. . For open valleys (valley lining exposed) lined with metal, the valley lining shall be not less than 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table 905.2.8.2. Asphalt shingles shall be fastened to solidly sheathed decks. Asphalt shingles shall be used only on roof slopes of two units vertical in 12 units horizontal (2:12) or greater. Liquid-applied roofing shall comply with ASTM C836, C957, D1227, D3468, D6083, D6694 or D6947. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. For SI: 1 ounce per square foot = 0.305 kg/m, The installation of modified bitumen roofing shall comply with the provisions of this section and the manufacturer's, Modified bitumen roofing shall have a design. Foam plastic materials and installation shall comply with. A liquid-applied protective coating that complies with Table R905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam. Asphalt shingles shall comply with ASTM D3462. Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with, Flashing against a vertical front wall, as well as soil, A drip edge shall be provided at eaves and rake edges of. Asphalt shingle packaging shall bear a. In areas where there has been a history of ice forming along the eaves causing a backup of water as designated in. ASTM B209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum thickness for pressformed shingles. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. arrow_right. Sheathing Requirements R905.2.1 Asphalt shingles shall be fastened to solidly sheathed decks. The lecture and activity format allows participants to discuss the changes, reasons for the changes, and answer knowledge review questions. Base and cap flashing shall be installed in accordance with manufacturer's instructions. Table R803.1 is for roof sheathing which requires 5/8 plywood with rafters 24" o.c. Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. Wolf Hollow Chapter 1, Fayette County Magistrate Court Wv, Airbnb With Hot Tub Greensboro Nc, 2017 2018 Unc Basketball Roster, Mercari Ship On Your Own Option, What Is Chip Kullik Doing Now, Barbara Meshad Dooley Age, The Glamorous Imperial Concubine Happy Or Sad Ending, A liquid-applied protective coating that complies with Table R905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam. Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. CONTINUE WITH CODE REQ'S Where the existing roof covering is slate, clay, cement or asbestos-cement tile. Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. 26 gage [0.019 inch (0.5 mm)] corrosion-resistant sheet metal and shall extend not less than 11 inches (279 mm) from the centerline each way. Interlayment shall comply with ASTM D226, Type I. SECTION R804 COLD-FORMED STEEL ROOF FRAMING. PDF Guidelines for asphalt shingle roofing - Minnesota Asphalt shingles shall be tested in accordance with ASTM D7158. Asphalt shingles shall be used only on roof. Asphalt shingles shall be used only on roof. Adjacent segments of drip edge shall be overlapped not less than 2 inches (51 mm). Same as Maximum Ultimate Design Wind Speed, Apply in accordance with the manufacturer's, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B 370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet, ASTM B 209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum, Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, As an alternative, self-adhering polymer-modified bitumen, The standard calculations contained in ASTM D 7158 assume Exposure Category B or C and. Class A, B or C roofing shall be installed in, Flashings shall be installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet, Flashings shall be installed at wall and roof intersections, wherever there is a change in roof, A cricket or saddle shall be installed on the ridge side of any, The requirements set forth in this section shall apply to the application of, ASTM D6380 Class M mineral-surfaced roll roofing. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. The 2020 Minnesota Residential Code adopts the 2018 International Residential Code (IRC). Adjacent segments of drip edge shall be overlapped not less than 2 inches (51 mm). DEWALT Building Code Reference: Based on the 2018 International Nails shall be corrosion resistant and not less than 11-gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. The installation of asphalt shingles shall comply with the provisions of this section. Where required, an ice barrier shall comply with Section 905.1.2. For SI: 1 ounce per square foot = 0.305 kg/m, The installation of modified bitumen roofing shall comply with the provisions of this section and the manufacturer's, Modified bitumen roofing shall have a design. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. The second R-value applies when more than half of the insulation is on the interior of the mass wall. The installation of liquid-applied roofing shall comply with the provisions of this section. Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. or less. or less, R905.2.4.1 Wind Resistance of Asphalt Shingles, R905.14 Sprayed Polyurethane Foam Roofing, R905.17 Building-Integrated Photovoltaic (BIPV) Roof Panels Applied Directly to the Roof Deck, Section R907 Rooftop-Mounted Photovoltaic Panel Systems, R907.1 Rooftop-Mounted Photovoltaic Panel Systems, Building-integrated photovoltaic products. A base sheet that complies with the requirements of. Allowable spans for lumber sheathing shall conform to IRC Table R803.1. Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. 12 oz/sq ft for preformed metal shingle systems. Drip edges shall extend not less than. PDF 2018 IRC UPDATE Handout 9-1-18 - ICC 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Wood shakes shall comply with the requirements of Table 905.8.5. 2018 IRC. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum 3 / 8 -inch- diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than 3 / 4 inch (19.1 mm) into the roof sheathing. Minimum headlap for slate shingles shall be in accordance with Table R905.6.5. Valley flashing shall be not less than 15 inches (381 mm) wide. Thermoplastic single-ply membrane roofs shall have a design. Copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. Thermoset single-ply membrane roofs shall have a design. Slate shingles shall comply with ASTM C406. Asphalt shingles shall be fastened to solidly sheathed decks. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum, Asphalt shingles shall have the minimum number of fasteners required by the manufacturer's, Where required, ice barriers shall comply with, Flashing for asphalt shingles shall comply with this section and the asphalt shingle manufacturer's, Base and cap flashing shall be installed in accordance with manufacturer's instructions. Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. Drip edges shall extend not less than. Mineral-surfaced roll roofing shall not be applied on roof. Flashing and counterflashing shall be made with sheet metal. A base sheet that complies with the requirements of. Asphalt shingles shall comply with ASTM D3462. About this chapter: Chapter 10 contains requirements for the construction, seismic reinforcing and anchorage of masonry chimneys and fireplaces; and establishes standards for the use and installation of factory-built chimneys, fireplaces and masonry heaters. 2018, 2021 IECC: Mass walls shall be in accordance with Section R402.2.5 (N1102.2.5 in 2018 IRC). Slate shingles shall comply with ASTM C406. Section R804 Cold-Formed Steel Roof Framing Section R806 Roof Ventilation Section R807 Attic Access Chapter 9 Roof Assemblies The installation of wood shakes shall comply with the provisions of this section. arrow_right. Valley flashing shall be not less than 15 inches (381 mm) wide. R905.2.4.1 Wind Resistance of Asphalt Shingles, R905.14 Sprayed Polyurethane Foam Roofing, Section R907 Rooftop-Mounted Photovoltaic Systems, R907.1 Rooftop-Mounted Photovoltaic Systems, Section R909 Rooftop-Mounted Photovoltaic Panel Systems, Building-integrated photovoltaic products. Slate shingles shall be secured to the roof with two fasteners per slate. Wood shakes shall comply with the requirements of Table R905.8.5. Each bundle of shakes shall be identified by a, The installation of built-up roofs shall comply with the provisions of this section and the manufacturer's. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. Stainless steel fasteners are acceptable for metal roofs. If re-roofing over wood shingle, or wood shake roofs, additional code requirements may apply. Htt4 & -`P .+Yn0a|bZN4U+yX*iNFk $ Part III Building Planning and Construction, R907 Rooftop-Mounted Photovoltaic Panel Systems, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T [RE] Solar-Ready ProvisionsDetached One- And Two-Family Dwellings and Townhouses, The provisions of this chapter shall govern the design, materials, construction and quality of, Roofs shall be covered with materials as set forth in Sections, Flashings shall be installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet, Flashings shall be installed at wall and roof intersections, wherever there is a change in roof, A cricket or saddle shall be installed on the ridge side of any, The requirements set forth in this section shall apply to the application of, ASTM D6380 Class M mineral-surfaced roll roofing. arrow_right. In areas where the average daily temperature in January is 25F (-4C) or less, Wood shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Above-deck thermal insulation board shall comply with the standards in Table R906.2. Base flashing shall be of either corrosion-resistant metal of minimum nominal 0.019-inch (0.5 mm) thickness or mineral-surfaced roll roofing weighing not less than 77 pounds per 100 square feet (4 kg/m. The installation of asphalt shingles shall comply with the provisions of this section. 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. 1. For SI: 1 ounce per square foot = 0.305 kg/m. satisfy the requirements of 2021 IBC Section 1512, 2018 and 2015 IBC Section 1511, 2012, 2009 and 2006 IBC Section 1510, 2018 and 2021, 2018 and 2015 IRC Section R908 or 2012, 2009 or 2006 IRC Section R907. Roof valley flashing shall be not less than No. R803.1 Lumber sheathing. Base flashing against a vertical sidewall shall be continuous or step flashing and shall be not less than 4 inches (102 mm) in height and 4 inches (102 mm) in width and shall direct water away from the vertical sidewall onto the roof or into the gutter. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. Slate shingles shall be secured to the roof with two fasteners per slate. The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. Real wood. Thermoplastic single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Nominally, 2-by- redundant requirements for stud nailing, and create consistency in the IRC for roof sheathing attachment. For open valleys (valley lining exposed) lined with metal, the valley lining shall be not less than 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table R905.2.8.2. Mineral-surfaced roll roofing shall conform to ASTM D3909 or ASTM D6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions. Paint systems in accordance with ASTM A 755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A 792, ASTM A 875, ASTM A 463, or ASTM A 653. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum, Asphalt shingles shall have the minimum number of fasteners required by the manufacturer's, Where required, ice barriers shall comply with, Flashing for asphalt shingles shall comply with this section and the asphalt shingle manufacturer's, Base and cap flashing shall be installed in accordance with manufacturer's instructions. Chapter 9: Roof Assemblies, 2018 South Carolina Residential Code | UpCodes Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Asphalt shingles shall be tested in accordance with ASTM D7158. Part III Building Planning and Construction, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T [RE] Solar-Ready ProvisionsDetached One- And Two-Family Dwellings and Townhouses, The provisions of this chapter shall govern the design, materials, construction and quality of, Roofs shall be covered with materials as set forth in Sections 904 and 905. Each bundle of shakes shall be identified by a, The installation of built-up roofs shall comply with the provisions of this section and the manufacturer's. Mineral-surfaced roll roofing shall not be applied on roof. Mineral-surfaced roll roofing shall be fastened to solidly sheathed roofs. Materials and methods of application used for recovering or replacing an existing, The structural roof components shall be capable of supporting the, Flashings shall be reconstructed in accordance with, Chapter 9 addresses the design and construction of, The 24 inch measurement shall be along the, Building-integrated photovoltaic products. Liquid-applied roofing shall have a design. Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. Roof penetrations shall be flashed and sealed in accordance with this chapter. The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. For open valleys (valley lining exposed) lined with metal, the valley lining shall be not less than 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table R905.2.8.2. 2018 International Residential Code (IRC) COPYRIGHT PREFACE EFFECTIVE USE OF THE INTERNATIONAL RESIDENTIAL CODE arrow_right CHAPTER 1 SCOPE AND ADMINISTRATION arrow_right CHAPTER 2 DEFINITIONS arrow_right CHAPTER 3 BUILDING PLANNING arrow_right CHAPTER 4 FOUNDATIONS arrow_right CHAPTER 5 FLOORS arrow_right CHAPTER 6 WALL CONSTRUCTION arrow_right %PDF-1.6 % For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s. Roofing Guide to the International Residential Code (IRC) - Roof Online The installation of liquid-applied roofing shall comply with the provisions of this section. Copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs. Flashing for asphalt shingles shall comply with this section. Valley flashing shall be not less than 15 inches (381 mm) wide. Section R901 General R901.1 Scope The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. Water soaked or deteriorating decking must be replaced. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Paint systems in accordance with ASTM A755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A792, ASTM A875, ASTM A463, or ASTM A653. Slate shingles shall be secured to the roof with two fasteners per slate. Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. For closed valleys (valley covered with shingles), valley lining of one ply of smooth roll roofing complying with ASTM D6380 and not less than 36 inches wide (914 mm) or valley lining as described in Item 1 or 2 shall be permitted. Spaced lumber decking CoL Refer to the manufacturer's technical bulletin regarding requirements for existing deck boards. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum, Asphalt shingles shall have the minimum number of fasteners required by the manufacturer's, Where required, ice barriers shall comply with, Flashing for asphalt shingles shall comply with this section and the asphalt shingle manufacturer's, Base and cap flashing shall be installed in accordance with manufacturer's instructions.

Umbral Language 5e, Articles OTHER

Comments are closed.