Christin, many aboveground pumps plug into a GFCI outlet, check that the TEST button is not popped out. 3. inspect clock and rear of motor for any obvious signs of damage, like watermarks, dirt, insects or something burned or melted I replaced the impeller ring and noticed it There is also a faint burnt odor. Great site. Anything I can do on my own to fix this? All pipes are 1.5 and solidly installed with primer and high quality glue for the PVC used. Additional causes for low water flow in your pump are debris build-up or dirty equipment. I was only able to read and yes feel voltage in the pool when the main pump was running only. You need to use a K-1766 salt test kit or a calibrated meter. A spike below 100V or above 140V, could blow a capacitor. Hi there, I made the very unfortunate decision to rent my home to a friend. With the pump off, remove the basket and reach your hand back into the eye of the impeller. Sandy, some hoses are clamped onto hose adapters, using a worm clamp or radiator clamp that tightens the hose to the hose adapter. Replacement for Hayward T-Cell-15. Should it be very hot to touch or is this an indicator for a capacitor problem? How To Recalibrate The Average Salt Level. Motors have a thermal overload switch which will shut off the motor if it gets too hot to operate, and in such cases, it will turn itself back on again after it cools, usually in 15-20 mins. Hi Davy, I have a Hayward Super II which has been running well for years. Check for possible disruption inside of the flow T. Installation requires 12 inches of straight pipe before the flow switch. Otherwise if not, you go in thru the back of the motor, remove the capacitor bracket to drop the cap out of the way, so you can slip a 7/16 wrench on the slotted back 1/2 of the shaft, and work it back and forth for 30 seconds to break the rust. I just replaced my pool pump motor because it was really loud and i figured it was the bearings. We have all these parts here: https://www.intheswim.com/c/valve-parts, I Installed a new Hayward VCSB216V solar pump. There was a slight drip coming from a fitting, that I tightened. Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. They are easily replaceable. Royal Tulip Beach Resort is located near Port Ghalib, 42 km from Marsa Alam. Second most common air leak on a Super Pump would be the incoming pipe fitting. (Yes, literally now.). Troubleshooting pool heaters is a methodical process, or a process of elimination. Check the wiring of the pump cord, comparing to the wiring diagram printed on the motor, to be sure that they are connected properly, should be wired for 115V (not 230V). There are two washers that I have on each side of the spring. The breaker on the panel tripped. Never had an issue with the other motors we have had. Went to clean the pool filter a few days later and now when turning on the pump it made a loud grinding noise. Hi Ernesto, hmmm, Im not quite sure, but sounds like it could be either low voltage, or a loose connection, or something mis-wired between the terminal board and the capacitor? It could be a problem the other way around, AG pumps cannot lift water vertically, so are not used on inground pools. Hi David, spilling water on the motor is no problem, they do fine outside in the rain (flooding is a different story) Have you checked the GFCI test button on the outlet? The most common cause for this is turning the valve with the pump on, or not pushing the valve handle down fully as the valve is re-positioned. Hi There I have a Hayward Super Pump VS pump. I removed it and put the old pump back (20 years old), it works and does not shut down. After removing the capicitor and the thermal load, we were able to get a 7/16 wrench on the shaft at around 12 oclock, but the shaft only has two flat sides and we are only able to move the shaft like 1/12th of a revolution clockwise and counter-clockwise (back and forth between 11 and 12 oclock). Reinstalled Same problem recycled power. I sent a sample to the store and my salt level is 3400 and the reading shown is 4300. Check in morning and basket is half full with water trickling in basket. In either case, a new vacuum hose of good quality should fix the issue. ? No lights are coming on as if no power. My pump seems to be working fine but Im having an issue with the flow pulsating out of the filter. The electrician also installed w new capacitors on the pump and still same problem. Hello, Im having an issue where my variable speed pump is pushing de back into the pool however it only does this when its running at a lower RPM and does not exhibit this issue when running at priming speed or a higher RPM. For the pool winterization, the usual practice is to remove the filter and drain plugs, and then use rubber expansion plugs, or threaded plastic plugs, to close up the pool skimmer line and the pool wall return lines (where water returns to the pool), after the pipes are drained of water. Does a Hayward super pump wired on 230v have to have a controller?.. My pump is one horse power. BTW, this can be caused from a water hammer effect, running the pump and then shutting off flow suddenly, or the fitting could have been overtightened to begin with, 7 years ago, and age caused it to give way. If youre correct that theres a problem with the internal bypass, what should I do? Hayward recommends 1.5 PVC pipe, and more than one line, (i.e. put in a new motor and had the old motor repaired. You can remove the wires and call your local Electric Motor Repair Shop, and see if they have this capacitor in stock, just read them the MFD number range printed on the side of the black cylinder. Hi Doug, good question that indicates that there is an air leak coming into the pump. I think the problem is a nick in the face of the salt cell that the unions o-ring seals against, but I cant feel anything there so its not like a giant burr or anything. this is the black cylinder in the rear, at 9 oclock. After communication is established, if it is lost for 30 s, the error will be displayed. Initially, look into the pump/strainer housing. My 2 year old 1.5 HP above ground Hayward pool pump worked fine last year. I turned power off from breaker, emptied basket, used fingers to check for debris in impellers, did not find any. Thanks for the comment! I tried replacing that oring and the leak got worse somehow and it just doesnt feel like there is any pressure when tightening the 6 bolts that hold the pump and motor together. Hi Joe, could be a relay clicking, if you have a controller attached to the system, look for burnt or melted hi-speed relay. Thank you so much, (I just bought the house and am new to pool upkeep.). If any of these readings are outside limits, replace motor. It could also be the wiring from breaker to timer, or timer to pump, or just breaker to pump, if there is no timer or other switch (and if there is no other switch, the breaker is likely just worn out from overuse). I have been able to spin the motor shaft. It looks like no one has them in Stock and if I cant filter the pool, then it wont be usable. Spray off well, and soak in a 5-gal bucket, the entire Flex Tube Nest, for a number of hours, hose off again, soak for another few hours, hose off thoroughly, dunk in the pool a few times, then replace in the filter tank. I have perhaps a really basic question I just cannot get one side of my salt cell to seal with the union. That is usually what causes the rattle. Hey John Theres a few ideas to check, good luck! pool water analysis near me; camel leather reclining sectional; chiaogoo twist shorties set; 24 emsco resin hydro pickers garden system; pool cover 16x10 oval; I purchased it June of 2018. Now if its not an air leak, surging can also be caused by a clog in the pipe, usually a solid object like a golf ball, getting sucked back and forth in the pipe. Hi Freddy, usually a clicking noise may be a relay, which are used in control systems for pools. I checked pool water supply and dont feel any water coming but my pump is still running but nothing is moving in pool. Flip timeclock switch on, inspect time clock motor gears (Intermatic clocks) for good timer motor, and inspect wiring from timer to pump. 908-355-7995. I didnt plug the line and got a lot of water on the pump motor. Hooked it up the same as the last motor and left the setting to 230 as that is what the last motor was set to run on. The hotel has an excellent location, close to a wonderful coral reef, lagoon with natural pool and sandy beach, outdoor swimming pool available all year round, private beach area, kitesurfing center and bar. Also check that water level is good in pool, and skimmer weir is not blocking water flow. The higher the pump is elevated above the water level, the more struggles this can cause. The motor on my Hayward super pump 2 went out so I ordered a Hayward replacement. Is it problem of filter ? Also in reviewing the setup, the salt water panel box does not even turn on on low. Hello. Inherited an old Hayward super pump that hums but doesnt turn over, checked the shaft which moves smoothly and replaced the starter capacitor to no avail. It could also be something wrong with the motor, something internal with the windings, or shaft, or bearings, causing excess heat. After running the pool for a few hours we realized the pump was leaking and EXTREMELY HOT. Since you didnt say it trips a breaker, its probably not a short or ground-out of power, although it still could be, typically a wire touching metal other than the terminals on both end of the wire. Gasket Maker. Hi Michael, sounds like the capacitor may be bad, located at 9 oclock in the motor rear, replace with exact same MFD rating. Well, the good news is you are at the right spot and youre definitely not alone. Thank you. heres the motor: https://www.intheswim.com/p/hayward-super-pump-pool-pump-motor-1-5-hp-threaded-shaft and the seal: https://www.intheswim.com/p/hayward-super-pump-shaft-seal-assembly-spx1600z2. You can assist by removing the back cover and placing a fan behind the motor and try again after a day. If from the center of the lid around the stem, you can replace the two small stem o-rings, but sometimes the stem is worn down and needs replacement. Hi, I have 2 issues with my 1530 above pool. Then sometimes with no rhyme or reason the pump shuts down and will not come back on until after I turn off and on all breakers. It's the same as an aquarite with a T-5 cell. But most aboveground pool pumps are 115V, and certainly is if it came with the cord. Hi Davy~ Any suggestions? Seal up the air leak in the front of the pump, then bleed off all the air in the filter tank, and the bubbling should cease. Good morning. I have it set for a T9 cell. Does it really need to be replaced? Setting it up this year and the pool filter lid keeps leaking. 8. check power at the motor, with a multimeter set on 240V+ place test probes on the brass screws or terminals where the two power wires connect. Hi Frank, so it ran for weeks or more on 115V, when set to accept 230V, and then it started overheating, and then ran great for about a month, but now it makes no noise at all. I am getting a CEL code and the heater will not run. It doesnt mean it is ready to go at 230. Hi Tiffany, in most inground pool cases, the pool pump should be powered by a breaker on the home main panel, which powers a breaker on the pool equipment pad sub-panel breaker box. HAYWARD SALT CHLORINATOR SYSTEM 35K - BLUE ESSENCE-35 This is wholesale site for our registered customers. Is the replaced pump and motor problem? This usually means the motor needs to be replaced. Heyward 1.5 hp runs for a while and then top of pump pops off when I reset it works for a while and then pops again could It be pressure building up due to dirty filter? I would also check all the wire connections (power off) to be sure they are tight, on the breaker and on the time clock, and also inspect for insect infestation, or lizards, mice, etc. An electric motor shop local to you could test them, perhaps for free or low cost. On traditional intermatic time clocks, you also have to make sure the timer dogs are tight, or they can slip, use pliers to tighten the nut tighter to avoid. Incorrect sizing can cause multiple problems, including low water flow. i hope this helps, but I am also maybe missing something. New gauge was ordered. any ideas? Put your foot on the motor and apply a little weight, to see if the noise stops. Seems like filter is dirty , so I bumped it several times (once with motor on to really force water through) that usually does it. "image": {
Like it is locked up. My Hayward xstream filter pump is not turning on at all. how to watch past broadcasts on twitch. For AquaRite, move the switch from auto to off and check all of the readings. If the motor is still giving you a drive stall error, it probably means that you need a new drive. Maintenance. That is the black cylinder in the rear of the motor, located at 9 oclock. It could also be the centrifugal switch located in the rear of the motor, on the end of the shaft, check for looseness, broken spring or other damage. Incorrect size breaker powering the outlet (below 15 amps). I believe I have a bad capacitor. Ohms reading should be between 0.5 and 1.0 ohms max. Sun was beating on it. If regular loudness, its likely an air leak. Hi Robin, an F5 code? Make sure you. info. Pumps normal pressure and pulls enough volume to keep bakery full. The pump is connected after the filter and before the salt chlorinator. Hi Tom, if it is the same exact pump and pump size, that would be unusual, but if its the same horsepower, but a different pump model, that would be the simplest answer. If you have a visible motor shaft, just behind the impeller, common on older pumps or booster pumps, you can just grab it with straight pliers and turn it back and forth. Is this normal? What can I do? If none of those, it likely is an internal short across the wirings, or a bent shaft, which is the end of that motors life. Thanks. Hi Heidi, it sounds like maybe the plumbing could be reversed? Hope thats not the case. The control panel says that theres a driver error. Also check the pump basket, and possibly the pump impeller may be clogged, but Id first clean the filter. replacement. I have an aboveground kayak saltwater system . This error can result commonly in springtime, after the pump has sat all winter rust can develop between the stator and rotor. I checked the breakers, plumbing, control panel, plumbingjust need to know if I shud prepare myself to buy a replacement. Yes this pool was install without GFCI protection, (of course we will installing an equipment ground and GFCI Breakers.) 3. slide pump backwards, out of the housing, remove diffuser and wear ring from impeller We have just replaced the seal assembly as suggested by a Hayward rep already. Check the tightness on all wire connections, on the breaker, timeclock and motor. If I push down on the the cover or apply weight to the top, the vibration reduces significantly. EC65 uses 6 lbs, and EC75 uses 9 lbs, but since DE is half as light as others a lb of DE powder is more than 2 cups of dry measure, its actually closer to 4 cups. Upon resetting an electrical short sound came from the pump motor tripping the breaker a second time. I would recommend getting a plug-in timeclock so you dont need to plug/unplug it all the time. If your hose has union connections that are tightened to connect to the filter, you may try some Teflon tape on the valve threads, or may need a new hose assembly, if the union threads are damaged. Had the filter for 3 years. Two going bad? We have a Hayward 1.5 lx. "address": "",
I can turn the switch to low and it will start and run then switch to high. Hi Cindy, most likely an air leak. Chlorinator Pro CP-15 Cell. I will re-check all the wiring. Should I have it checked or is this normal? Hi John hot plug? Check that the pump lid is on very tight, and that the threaded fitting that screws into the front of the pump has Teflon tape or other thread sealant. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. HI Alberto, if a motor is overheating, it normally takes about 15-20 minutes, and then the thermal overload switch, located in the rear of the motor, will trip, shutting off the pump for about 15-20 minutes, until it is cool enough to start again, on its own. Hi Tony, there could be a short in the motor, or loose wires connecting to the capacitor, or if the capacitor you are replacing with is not the correct capacitor, or if the centrifugal or stationary switches are not releasing the capacitor, due to loose or misaligned switches, or loose wires, or wires shorting out by touching other wires or the motor casing, or crimped wires give a good look around the back of the motor, and try another capacitor, maybe call Hayward and ask for the correct capacitor MFD number for your horsepower of Northstar. Then, I tried plugged the pump into another power outlet and it still does not work. Flip circuit breaker all the way Off, then back on again. Or using a Clarifier after vacuuming can also be a solution. I have a Hayward super pump 1.5 hp. Thanks in advance for any help. }
. If not, keep reading. If this is an ABG pool, check the skimmer hose and adapter fittings. I used the override switch and it fired up and left it on for several hours then turned it over to auto and it worked again but has since stopped. It is a generic Hayward pump with 1 HP. If the shaft is free turning, but the pump does not turn on, check power connections. Most likely, and unfortunately yes. I need some advice for my 15 x 30 x 48 AG oblong swimming pool. 4. A pool guy who has since stopped operating put it in. We just has this pool installed year, and brought the motor inside the house. For the green water, drop the pH to 7.2 and add enough shock until the water turns blue-ish, and run the filter 24/7. I get home from work and the pump is running. If you remove the motor from the pump, and then turn on the power very briefly if the noise continues, its the bearings, if it runs quiet (high speed), then look to vibration or cavitation. Why does this keep happening? After the click, immediately push the diagnostic button 5 times to begin the recalibration stage. Hi Jeanette, somewhat normal with sand filters I would say first. Hi Chris, is the vacuum hose fully primed with water before you attach it to the skimmer, you say primed and ready to go, so I assume so. Then there is often a switch or a timeclock that is wired in between the sub-panel and the pump. Outlet works fine. i cleaned the filter put the cover back on turned the pump but it doesnt seem to be priming . Hi Rob, normally sunshine will not cause a motor to overheat, but if it is having other internal issues generating heat, it could push it over the limit. Now it wont flip back on but it is still raining hard. Could this be true? They dont usually begin to flow like a gusher, but a steady trickle. The loud noise could be the bearings, or it could be the impeller having come off the shaft and contacting the volute if you have an older bronze or brass pump, with an impeller that uses a stub shaft. But heaters? Hmmm, should work? I do not think its the breakerits relatively new. Could also be a loose high speed wire from the switch. Whats the problem. The most likely is an air leak, and the usual places are 1) pump lid not tight enough or not lubed, or bad o-ring, or loose drain plugs (or without thread sealant or o-ring). Also installed a brand new circuit box to allow for the bigger pump its a 20A GFCI breaker with 12 gauge wire going to the pump. What happens when you switch the output to super-chlorinate? If not, you should cut out the fitting and replace, smearing on some Blue RTV sealant, and then wrapping the threads completely in 3-4 layers of Teflon tape before screwing it into the pump. Theres no sound, when we hit the power switch no power. Recently replaced mortor and pump. If you see no gears moving, the timer motor may be dead. Check power at the switch or timer in the same way as the motor, at the other end of the wires running between the switch/timer and motor. Have a Hayward SuperPump. Ive tried connecting direct from circuit breaker, as well as bypassing with a timer. Reinstall and add new DE powder. Some pumps are a bit difficult to remove, even when you have removed the right bolts/clamp sometimes they need to be pried apart with a screwdriver, to separate the pump. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. We replaced the handle assembly and valve per Hayward tech support that hasnt fixed the problem. Did we just ruin our pump?? I have great circulation, but I the problem is after the pump runs for around a half hour on the filter setting it barely has any force coming out of the jet. On attempting to open the pool, the motor started humming. $579 + Free Shipping in USA. I have purchased a Hayward SP 158015 Power-floLX series 1 1/2 horsepower Above Ground pool pump along with a Hayward S166T Proseries sandfilter 16 inch top mount for a 15 ft above ground proseries pool. The new pump is exact same model and when not connected to system it spins and runs fine. Have had it for 4-5 years and have had no issues. i know there is a low spead and hit speed switch when i take off the cover but it looks ok. it seems like the contacts get stuck together preventing the pump to turn on? . Do we need a new pump or can the electrical cord be replaced? When he went to turn the pool back on it made a slight humming noise like it was trying to come back on but it wouldnt turn on. We have a Hayward Swimpro Lx 1.0 hp and have a slow leak coming from underneath, maybe in between the housing and the motor. Went to start the pump to prep the pool for the kids and sill attempt to turn on but then stops. There is a small sump pump also connected to another breaker inside the breaker box that has no issues, of course it only runs a few minutes when it rains heavy to move water out of the basement. Troubleshooting Your Hayward Aqua Rite System - http://bit.ly/2RC8myGHayward AquaRite Parts - http://bit.ly/2NPGXbjHow To Clean a Hayward AquaRite Turbo Cell. Hi I have a Hayward aquatrol above ground pool chlorine generator system. A wire connected to the terminal board may be loose or burnt. Hello, my salt generator seems to be always be producing at 100% no matter what my output dial is set at. Third possibility is the pipe size is too small, and your 90 gpm pump may be starved for water. I have a pump that wants to stop pumping water after a few minutes the flow gets very low. Tried recalibration and no change. I have an sp3400vsp pump. About two weeks ago, my pool water level was very low and I believe this is were the air bubbles first presented. Be sure that all pool valves are open and any wall plugs are removed before turning on pump. Any ideas on what may be going on? We opened our pool a week ago and havent had a problem until today (May 23. It DOES turn on. Hayward Super Pump, 1 Hp running on 240V, 3 yrs old Hi Davy, Hi, my above ground pool pump will run when not attached to the pool and there is no water in it, but when I get it hooked up to the pool and let the hoses and pump fill, it no longer turns on. Big difference, but other than that, they operate pretty much the same! Used Cozzia Massage Chair, I just purchased a brand new Hayward Super Pump 1.5HP for my pool that is being renovated. larger hp motors, are not reversible. To keep the water clear, hand feed liquid or granular chlorine daily, and brush/skim the pool daily. Hi, my Hayward super pump is thermo protected. "@type": "Organization",
Hi With a flashlight (and your glasses), you can also look into the Visual Motor Check hole in the top of the mechanism, you should see gears moving. Also that some circuit breakers used can create such noise as to cause problems with this error message. The fact that it runs all day fine with a HD power cord attached and plugged in, makes me think its not a motor issue. Profile, Create a Pool Improper voltage wiring is the usual culprit for smoking pump motors. Check the breaker inside the house, make sure its not tripped. i just installed a vspnp hayward pump and when i flip the breaker on it only makes a clicking noise. It seems the pump is more powerful than last year ? It trips 20amp breaker after running 5 or 10 second. Any suggestions? You must log in or register to reply here. It leaks from the impeler case and is noisey, so assy B is no replacement. This troubleshooting guide should give you all the tools and understanding you need to tackle any issue with your Hayward pool pump with confidence! The leak and the surging you are experiencing, could be a result of the high filter pressure. Oh, and prepare yourself, a new motor or pump may be needed soon. Thats all I can think of now. If i knew what make/model of pump you have, I could be more specific. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. Im still getting air? Or maybe the glue that Im assuming is no longer working? I replaced the pump thinking it was bad. If error still occurs, replace drive. So, check that the air vents on the motor are not clogged, and that the fan in the rear is not clogged, or doesnt have something wrapped around the fan, and also around the pump, check that air flow is not blocked by mulch, or by pump being installed in a small box, or anything that prevents free flow of cool, outside air. First inspect wiring, to be sure everything is tight and secure, and there are no loose wires, or anything that looks wrong back there. Motor running very hot, almost like in a bind. Also they winterized the place where the water circulates inside the pool and it wont unscrew so we can let some of the water out and put the original piece back on. The situation is either an air leak in FRONT of the pump, around the pump lid, the pipe coming into the pump, or leaky suction side valves. If it does make a humming or buzzing sound briefly and trips the breaker, check that the shaft rotates the impeller freely, and if so, replacing the capacitor is usually the fix. Step 3: Double check the wires on the flow switch for damage. This is a brand new pump out of the box that was installed and the inlet is drawing water in and filling basket and the outlet is discharging water but it just trips the breaker everytime. If stuck from rust build-up, move the capacitor (located at 9 oclock) and/or the thermal regulator (located at 12 oclock), out of the way, so that you can fit a 7/16 open end wrench on the slotted part of the shaft, behind the centrifugal switch that is screwed onto the end of the shaft. How can I secure the top to the filter so the water will not pour out of it while the pump is on filter mode? If not, use an outlet tester or plug in a different appliance (light, hair dryer, fan) to see if the outlet has power. I would say you are likely needing a new motor, and pump. IF that all looks good, consider replacing the capacitor. When it shuts off, you could also test power, to be sure power is still reaching the motor, with a multimeter tester. Does it turn on again by itself, about 20 minutes later (after cooling down)? Could also be a loose wire connection, the power wires. If the salt level is within range, go to Step 3. Any thoughts? The pump may be reversible, able to accept either 115V or 230V, so the incoming voltage must match the set-up, +/- 10%. We replaced all the seals in the pump and ran a completely new line even from the pump directly into the pool and it will not hold prime. if this is installed below pool water level, also close the isolation valves, to keep the water in the pool, and avoid soaking your socks!